上海创赛科技有限公司
   
     
您当前的位置: 网站首页 > 产品展厅 >试剂盒 >Cyclosporine A (CsA) ELISA Kit|环孢素A ELISA 试剂盒(可测血浆/血清/体液/组织)
Cyclosporine A (CsA) ELISA Kit|环孢素A ELISA 试剂盒(可测血浆/血清/体液/组织)
  • 品牌:mybiosource
  • 产地:美国 United State
  • 货号:MBS774481
  • 发布日期: 2019-03-22
  • 更新日期: 2024-11-20
产品详请
产地 美国 United State
品牌 mybiosource
货号 MBS774481
检测限 10ng/ml -400ng/ml
数量 1
检测方法 elisa
标记物
样本 rat
应用 For Research Use Only. Not for use in diagnostic procedures.

产品名称:环孢素A ELISA 试剂盒(可测血浆/血清/体液/组织)

英文名称:Rat Cyclosporine A (CsA) ELISA Kit

标准曲线范围:10ng/ml -400ng/ml

灵敏度:1.0ng/ml

产品包装:

有效期:六个月。

储存:2-8.℃

样品:血清、血浆、细胞培养上清液、体液和组织匀浆

产品包装:48T/盒;96T/盒;5X96T/盒


Rat Cyclosporine A (CsA) ELISA Kit

Standard Curve Range: 10ng/ml -400ng/ml 

Sensitivity: 1.0ng/ml 

Expiration date:six months . 

Storage: 2-8 . ℃ 

For samples:Serum, plasma, cell culture supernatants, body fluid and tissue homogenate 


    When stored at 2 -8 °C unopened reagents will retain reactivity until expiration date. 

    Opened reagents must be stored at 2 -8 °C.

Intended Use 

    For the quantitative determination of Rat Cyclosporine A(CsA) concentrations in serum, plasma, saliva, urine, tissue homogenate, cell culture supernates and other biological fluids. 

Test Principle 

    The kit was used to test the level of Rat Cyclosporine A(CsA), based on the principle of biotin double antibody sandwich technology enzyme linked immunosorbent assay (ELISA). 

    Add Standard and Sample to the wells that pre-coated with objective antibody, then add streptavidin HRP to form an immune complex, incubation, by incubation and washing, removal of unbound enzyme, and then add the substrate A and B, then the solution will turn blue and finally change into yellow at the effect of acid. The color depth or light was positively correlated with the concentration of Cyclosporine A (CsA). 

Precautions 

  1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.

  2. It is highly recommended to use the remaining reagents within 1 month before the deadline. For the expiration date, please refer to the label on the kit box. All components are stable before this expiration date.Do not use kit components beyond their expiration date.

  3. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C) before use. Do not use water baths to thaw samples or reagents.

  4. Use only deionized or distilled water to dilute reagents.

  5. Each steps add sample, should use sampler, and often proofread the accuracy to avoid the test error. Use fresh disposable pipette tips for each transfer to avoid contamination.

  6. Test should strict accordance with the instructions of the operation, the test results must be determined by the microplate reader.

  7. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided. 

  8. Do not mix acid and sodium hypochlorite solutions.

  9. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.

  10. All samples should be disposed of in a manner that will inactivate viruses.

  11. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.

  12. Substrate Solution is easily contaminated. If bluish prior to use, do not use. Substrate B is sensitive to light and avoid prolonged exposure to light.


MATERIALS PROVIDED WITH THE KIT 


All reagents provided are stored at 2-8°C. Refer to the expiration date on the label. 

Reagents components 96 determinations 48 determinations 

  1. Microelisa stripplate 12*8strips 12*4strips

  2. 2. Standard A 0ng/ml 0ng/ml

  3. . Standard B 25ng/ml 25ng/ml

  4. 4. Standard C 50ng/ml 50ng/ml

  5. Standard D 100ng/ml 100ng/ml

  6. Standard E 200ng/ml 200ng/ml

  7. 7. Standard F 400ng/ml 400ng/ml

  8. 8. Sample Diluent 6.0ml 3.0ml

  9. 9. HRP-Conjugate reagent 10.0ml 5.0ml

  10. 10. 20X Wash solution 25ml 15ml

  11. 11. Chromogen Solution A 6.0ml 3.0ml

  12. 12. Chromogen Solution B 6.0ml 3.0ml

  13. 13. Stop Solution 6.0ml 3.0ml

  14. 14. Closure plate membrane 2 2

  15. 15. User manual 1 1

  16. 16. Sealed bags 1 1





Note: Standard (A → F) concentration was followed by: 0ng/ml ,25ng/ml ,50ng/ml , 100ng/ml ,200ng/ml ,400ng/ml. 


Materials required but not supplied 

1.37 incubator ℃ 

2.Microplate reader capable of measuring absorbance at 450 nm. 

3.Precision pipettes to deliver 2 ml to 1 ml volumes. 

4.100 ml and 1 liter graduated cylinders. 

5. Distilled water, 

6. Disposable test tube 

7. Absorbent paper 

8. Precision pipettes and disposable tip Specimen Requirements 


FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES。

联系方式
手机:4006087598